MOQ: | 1000 |
Price: | $0.5-2 |
Standard Packaging: | Wooden case |
Delivery Period: | 30 days |
Payment Method: | D/P,T/T,Western Union |
Supply Capacity: | 10000PCS/month |
Durable Forged End Accessories for Galvanized Steel Composite Insulators
Description :
Our forged end accessories are high-strength, precision-engineered components designed for galvanized steel composite insulators, ensuring reliable performance in overhead transmission lines, substations, and other high-voltage applications. Manufactured through advanced forging techniques and hot-dip galvanization, these accessories deliver exceptional corrosion resistance, mechanical durability, and long-term stability even in harsh environments.
Key Features :
Technical Parameters
Parameter | Specification | Remarks |
---|---|---|
Material | High-carbon steel (e.g., 40Cr, 35VB) | Forged for high strength |
Surface Treatment | Hot-dip galvanized (ISO 1461) | ≥80μm coating thickness |
Tensile Strength | ≥600 MPa | Verified by ISO 6892 testing |
Yield Strength | ≥420 MPa | |
Elongation at Break | ≥14% | |
Hardness | 140-160 HB | Brinell hardness scale |
Thread Standards | M16-M64 (metric), UNC/UNF (customizable) | Complies with ISO 898-1 |
Corrosion Resistance | Salt spray test ≥1,000 hours (ISO 9227) | No red rust observed |
Working Temperature | -40°C to +120°C | Suitable for extreme climates |
Design Standards | IEC 60120, IEC 61466, ANSI C29.11 | Customizable to other standards |
Rated Load Capacity | 70kN / 120kN / 160kN (or as required) | Proof load tested |
Dimensional Tolerance | ±0.5mm (critical interfaces) | CNC machining precision |
Product application :
These high-strength forged end fittings are critical components designed for use with galvanized steel composite insulators in various electrical and infrastructure applications. Their robust construction and corrosion-resistant properties make them ideal for:
1. Overhead Transmission & Distribution Lines
2. Substations & Switchgear
3. Railway Electrification Systems
4. Renewable Energy Projects
5. Industrial & Harsh Environments
Key Advantages for These Applications :
✔ Longevity: Galvanization prevents rust in humid/coastal climates.
✔ Safety: High load capacity reduces risk of mechanical failure.
✔ Compatibility: Matches global standards (IEC, ANSI, etc.) for seamless integration.
Why Choose Our Forged End Accessories?
Reliability: Rigorous quality control and testing (salt spray, tensile load, etc.).
Customization: Available in multiple sizes and configurations to match project requirements.
Global Supply: Trusted by utilities and EPC contractors worldwide.
![]() |
MOQ: | 1000 |
Price: | $0.5-2 |
Standard Packaging: | Wooden case |
Delivery Period: | 30 days |
Payment Method: | D/P,T/T,Western Union |
Supply Capacity: | 10000PCS/month |
Durable Forged End Accessories for Galvanized Steel Composite Insulators
Description :
Our forged end accessories are high-strength, precision-engineered components designed for galvanized steel composite insulators, ensuring reliable performance in overhead transmission lines, substations, and other high-voltage applications. Manufactured through advanced forging techniques and hot-dip galvanization, these accessories deliver exceptional corrosion resistance, mechanical durability, and long-term stability even in harsh environments.
Key Features :
Technical Parameters
Parameter | Specification | Remarks |
---|---|---|
Material | High-carbon steel (e.g., 40Cr, 35VB) | Forged for high strength |
Surface Treatment | Hot-dip galvanized (ISO 1461) | ≥80μm coating thickness |
Tensile Strength | ≥600 MPa | Verified by ISO 6892 testing |
Yield Strength | ≥420 MPa | |
Elongation at Break | ≥14% | |
Hardness | 140-160 HB | Brinell hardness scale |
Thread Standards | M16-M64 (metric), UNC/UNF (customizable) | Complies with ISO 898-1 |
Corrosion Resistance | Salt spray test ≥1,000 hours (ISO 9227) | No red rust observed |
Working Temperature | -40°C to +120°C | Suitable for extreme climates |
Design Standards | IEC 60120, IEC 61466, ANSI C29.11 | Customizable to other standards |
Rated Load Capacity | 70kN / 120kN / 160kN (or as required) | Proof load tested |
Dimensional Tolerance | ±0.5mm (critical interfaces) | CNC machining precision |
Product application :
These high-strength forged end fittings are critical components designed for use with galvanized steel composite insulators in various electrical and infrastructure applications. Their robust construction and corrosion-resistant properties make them ideal for:
1. Overhead Transmission & Distribution Lines
2. Substations & Switchgear
3. Railway Electrification Systems
4. Renewable Energy Projects
5. Industrial & Harsh Environments
Key Advantages for These Applications :
✔ Longevity: Galvanization prevents rust in humid/coastal climates.
✔ Safety: High load capacity reduces risk of mechanical failure.
✔ Compatibility: Matches global standards (IEC, ANSI, etc.) for seamless integration.
Why Choose Our Forged End Accessories?
Reliability: Rigorous quality control and testing (salt spray, tensile load, etc.).
Customization: Available in multiple sizes and configurations to match project requirements.
Global Supply: Trusted by utilities and EPC contractors worldwide.